Sale! Mecer Winner Pro 3000VA On-Line Tower UPS - ME-3000-WPTU View larger

Online only

Mecer Winner Pro 3000VA On-Line Tower UPS - ME-3000-WPTU

ME-3000-WPTU

New product

Features
• True double-conversion online UPS
• Wide input voltage range (110-300 VAC)
• Input power factor correction 0.99
• Output power factor 0.8
• Converter mode available
• ECO mode operation for energy saving (only available for 1-3KVA)
• Generator compatible
• Adjustable battery numbers only available for 6K and up models
• Smart SNMP works well with either USB or RS-232 together
• Emergency power off function only available for 6K and up models

More details

162 Items

In Stock

R 5,034 tax incl.

-R 200

R 5,234 tax incl.

More info

MODEL: ME-3000-WPTU
PHASE: Single phase with ground
CAPACITY: 3000 VA / 2400 W

(with AVR,Monitoring Software + Cable & Built-in Surge Protection) - Black

INPUT

Voltage Range
Low Line Transfer: 
160 VAC/140 VAC/120 VAC/110 VAC ± 5% (Ambient Temp.<35°C)
(based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)
Low Line Comeback: 
175 VAC /155 VAC/ 135 VAC /125 VAC± 5 % (Ambient Temp.<35°C) (based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)
High Line Transfer: 300 VAC ± 5 %
High Line Comeback: 290 VAC ± 5 %
Frequency Range: 40Hz ~ 70 Hz
Power Factor: ≧ 0.99 @ nominal voltage

OUTPUT
Output Voltage: 200/208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode): ± 1%
Frequency Range (Synchronized Range): 47 ~ 53 Hz or 57 ~ 63 Hz
Frequency Range (Batt. Mode): 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
Current Crest Ratio: 3:1

Transfer Time
AC Mode to Batt. Mode: Zero
Inverter to Bypass: 4 ms (Typical)
Waveform (Batt. Mode): Pure Sinewave 
Harmonic Distortion: ≦ 3 % THD (Linear Load), ≦ 6% THD (non-linear load)

EFFICIENCY
AC Mode: 90%
Battery Mode: 88%

BATTERY
Battery Type: 12 V / 9Ah
Numbers: 6
Typical Recharge Time: 4 hours recover to 90% capacity
Charging Current (max.): 1.0 A
Charging Voltage: 82.1 VDC ±1%

INDICATORS
LCD Panel: UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

ALARM
Battery Mode: Sounding every 4 seconds
Low Battery: Sounding every second
Overload: Sounding twice every second
Fault: Continuously sounding

PHYSICAL
Dimension, D x W x H (mm): 421 x 190 x 318
Net Weight (kgs): 27.6

ENVIRONMENT
Humidity: 20-90 % RH @ 0- 40°C (non-condensing)
Noise Level: Less than 50dB @ 1 Meter

MANAGEMENT
Smart RS-232/USB: Supports Windows 2000/2003/XP/Vista/ 2008, Windows 7/8, Linux, Unix, and MAC
Optional SNMP: Power management from SNMP manager and web browser

NOTE 1: Derate to 80% of capacity in CVCF mode or when the output voltage is adjusted to 200/208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.